Products of RedGPS

Dashcam comparison for video telematics

thumbnail

Three out of ten engines run on stolen fuel. How did Neotecnik decide to stop this problem?

Read more

Sales force

thumbnail

Track and digitize sales force operations

Ecosystem

Success story: Optimization and Maintenance Control

thumbnail

Program and manage all fleet maintenance and generate budgets without the need for additional personnel

Read more

GPS tracking focused on security: 2023 guide

thumbnail

Discover the top 20 solutions and tools for tracking, security, and end customers

Read more

Use case: Optimizing operations in mining

thumbnail

Discover how a virtual copilot in MDT terminals meets safety regulations and optimizes operations

Read more

Use Case: Cold chain traceability with Bluetooth

thumbnail

How efficient cold chain control drastically reduces losses and damages to goods?

Read more

Benefits of a Tracking App for your clients

thumbnail

One of the most critical activities in logistics management is asset control...

Read more

Manage all aspects of your business

thumbnail

Partners is the platform for RedGPS clients and distributors from which they can manage all...

Read more

Analogues de 0 5v y 0 10v Strela

Analogues-de-0-5v-y-0-10v "The fuel level sensors "STRELA" with analog output are used to connect any trackers that have a voltage input <10V (STRELA with 0-5V output) or 10V> (STRELA with 0-10V output). The sensors can be used in car tanks, tractors, and other machines with a nominal onboard voltage of 12 or 24V. In this type of vehicle, only sensors with a 0-5V output can be used (the special version of 0-7V is also possible). It is not recommended to install "STRELA" sensors with a 0-10V output voltage in vehicles with a 12V onboard voltage."

Specifications

Manufacturer Model Type I/O Battery Communication Methods
Strela ANALOGUES (DE 0-5V Y 0-10V) Sensor N/A No - External Power Supply

Features

Fuel Volume 0%, V  0* 0*
Fuel Volume 100%, V  Approximately 5* Approximately 10*
Supply Voltage, V  10-30 10-30
Maximum Charging Current, mA  100 100
Level Measurement Accuracy, % of length  ±0.1 ±0.1
Allowable Additional Error Limits, % ** Not more than 1.0 Not more than 1.0
Diagnostic Codes Yes Yes
Temperature Limits, °C  -40 - +65 -40 - +65
Mean Time Between Failures Not less than 12500 h Not less than 12500 h
Housing Protection  IP66  IP66
Electrical Power Consumption, W  <0.2 <0.2
External Sensor Dimensions, mm  L x 70 x 70 L x 70 x 70
Continuous Sensor Operation Time Without limitations Without limitations
Analogues-de-0-5v-y-0-10v